SM33-1-5-400-1
Circuit Breakers
CIRCUIT BREAKER
SM33-1-5-400-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Body Length
1.448 inches minimum and 1.510 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Terminal Type And Quantity
4 wire hook
-
Bushing Length
0.360 inches minimum and 0.380 inches maximum
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Body Style
single pole type
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 14.000 maximum at 200 pct all locations
-
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and hermetically sealed
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Fragility Factor
moderately rugged
-
Unpackaged Unit Weight
3.400 ounces
-
Mounting Surface To Terminal End Distance
1.524 inches minimum and 1.586 inches maximum
-
Circuit Protection Type
overcurrent all locations
-
Body Width
0.567 inches minimum and 0.629 inches maximum
-
Pole Quantity
2
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac all locations
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Ultimate Trip Time Per Pole In Seconds
6.500 minimum all locations and 30.000 maximum all locations