Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.369 inches minimum and 1.369 inches maximum

  • Pole Quantity

    2

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.495 inches minimum and 4.505 inches maximum

  • Boss Height

    0.120 inches minimum and 0.130 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Body Height

    3.807 inches minimum and 3.817 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    7.245 inches minimum and 7.255 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations and 70.0 amperes dc all locations

  • Arc Quenching Method

    deion

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Width

    4.120 inches minimum and 4.130 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.276 inches minimum and 0.286 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.369 inches minimum and 1.379 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Body Length

    9.370 inches minimum and 9.380 inches maximum

  • Case Material

    plastic

  • Ultimate Trip Time Per Pole In Seconds

    400.000 nominal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...