673-0693-00
Filters and Networks
FILTER,BAND PASS
673-0693-00
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
1.475 kilohertz 1st band pass and 1.675 kilohertz 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.125 inches nominal
-
Functional Terminal Type And Quantity
1 tab, solder lug input 1st function
-
Principal Circuitry Type Per Function
inductance-resistance 1st band pass
-
Reference Frequency Per Function
1.575 single radio interference pulses per second
-
Functional Terminal Type And Quantity
1 tab, solder lug output 2nd function
-
Principal Circuitry Type Per Function
inductance-resistance 2nd band pass
-
Output Impedance Per Function W/Source Across Input
600.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
40.0 minimum 2nd band pass and 6.0 maximum 2nd band pass and 6.0 maximum 2nd band pass and 6.0 minimum 2nd band pass
-
Output Impedance Per Function W/Source Across Input
600.0 ohms 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Body Length
2.531 inches maximum
-
Input Impedance Per Function W/Load
600.0 ohms 1st band pass
-
Overall Height
3.281 inches maximum
-
Frequency Band Width Per Function
2.325 kilohertz 2nd band pass and 2.525 kilohertz 2nd band pass
-
Operating Temp Range
-55.0/+70.0 deg celsius
-
Average Life Rating In Hours
20000.0
-
Input Impedance Per Function W/Load
600.0 ohms 2nd band pass
-
Mounting Facility Type And Quantity
2 threaded stud
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.0 1st band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.0 2nd band pass
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Body Width
1.781 inches maximum
-
Inclosure Type
hermetically sealed
-
Discrimination At Specified Frequencies Per Function In Decibels
40.0 minimum 1st band pass and 6.0 maximum 1st band pass and 6.0 maximum 1st band pass and 40.0 minimum 1st band pass
-
Body Height
2.969 inches maximum
-
Reference Frequency Per Function
2.425 single radio interference two phase to two phase
-
Specified Frequencies Of Discrimination Per Function
1.475 kilohertz 1st band pass and 1.675 kilohertz 1st band pass and 1.15 kilohertz 1st band pass and 2.00 kilohertz 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.875 inches nominal
-
Specified Frequencies Of Discrimination Per Function
2.325 kilohertz 2nd band pass and 2.525 kilohertz 2nd band pass and 2.00 kilohertz 2nd band pass and 2.85 kilohertz 2nd band pass