Technical Characteristics

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Unpackaged Unit Weight

    0.100 pounds

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.094 inches maximum

  • Pole Quantity

    1

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    1.840 inches maximum

  • Case Material

    metal

  • Specification/Standard Data

    96906-ms25244 government standard

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...