AFL11-1392-198

Circuit Breakers

CIRCUIT BREAKER

AFL11-1392-198

5925-00-683-2550

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct all locations and 7.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Unpackaged Unit Weight

    1.800 ounces

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    2.645 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Boss Height

    0.090 inches minimum and 0.165 inches maximum

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Manual Actuator Type And Quantity

    2 toggle

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    explosion proof and shockproof

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...