3X0411TSMG4-5CURVE3
Circuit Breakers
CIRCUIT BREAKER
3X0411TSMG4-5CURVE3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
4.740 inches minimum and 4.760 inches maximum
-
Body Style
multipole-multiple actuator type
-
Body Height
2.600 inches minimum and 2.620 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.020 inches minimum and 1.040 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.540 inches minimum and 3.560 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Unthreaded Mounting Hole Diameter
0.164 inches nominal
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Body Width
3.090 inches minimum and 3.110 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
1.020 inches minimum and 1.040 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Mounting Facility Type And Quantity
6 threaded hole and 3 unthreaded hole
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.0320 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations