000-0000-019
Circuit Breakers
CIRCUIT BREAKER
000-0000-019
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Length
0.703 inches nominal
-
Frequency In Hertz
400.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Body Width
0.750 inches maximum
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Mounting Surface To Terminal End Distance
1.812 inches maximum
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Body Length
1.094 inches maximum
-
Manual Actuator Type And Quantity
1 push-pull
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location and 2.000 minimum at 400 pct single location and 7.000 maximum at 400 pct single location
-
Pole Quantity
1
-
Case Material
metal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location and 5.0 amperes dc single location
-
Specification/Standard Data
96906-ms25244 government standard
-
Inclosure Protection Type For Which Designed
explosion resistant and moisture resistant
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Bushing Length
0.250 inches nominal
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing