04306-7123
Circuit Breakers
CIRCUIT BREAKER
04306-7123
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.735 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Body Width
0.750 inches maximum
-
Bushing Length
0.235 inches minimum and 0.265 inches maximum
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Case Material
metal
-
Specification/Standard Data
96906-ms25244 government standard
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac single location and 7.5 amperes dc single location
-
Reset Method
manual
-
Inclosure Protection Type For Which Designed
shock resistant and moisture resistant and sand resistant and explosion resistant and corrosion resistant and fungus resistant and hermetically sealed and dustproof and vibration resistant
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Unpackaged Unit Weight
1.813 pounds
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Body Length
1.094 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.840 inches maximum