Technical Characteristics
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Unpackaged Unit Weight
1.813 pounds
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant and hermetically sealed
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Body Length
1.094 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location and 15.0 amperes dc single location
-
~1
data on certain environmental and performance
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.840 inches maximum
-
Case Material
metal
-
Specification/Standard Data
96906-ms25244 government standard
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Frequency In Hertz
400.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.735 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Body Width
0.750 inches maximum
-
Bushing Length
0.235 inches minimum and 0.265 inches maximum
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns