Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Body Width

    0.673 inches minimum and 0.703 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Nonturn Device Location

    at 9 oclock

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.250 minimum at 200 pct single location and 43.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.859 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    vibrationproof

  • Nonturn Device Radius

    0.370 inches minimum and 0.380 inches maximum

  • Body Length

    1.122 inches minimum and 1.152 inches maximum

  • Unpackaged Unit Weight

    0.100 pounds

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.655 inches minimum and 0.685 inches maximum

  • Nonturn Device Diameter

    0.085 inches minimum and 0.095 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.