220833

Switches

SWITCH,THERMOSTATIC

220833

5930-00-694-9402

5930 - Switches

Detroit Switch Inc.

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    4.0 amperes inductive load third voltage

  • Contact Adjustability

    actuation point adjustable

  • Temp Sensing Element Type

    capillary tube-bulb

  • Contact Adjustment Range

    +140.00/+215.00 actuation point degrees fahrenheit

  • Mounting Method

    bracket and unthreaded hole

  • Contact Voltage Rating In Volts

    115.0 dc at sea level fifth voltage

  • Precious Material And Location

    contacts silver

  • Bulb Diameter

    0.688 inches nominal

  • Precious Material

    silver

  • Contact Voltage Rating In Volts

    230.0 ac at sea level second voltage

  • Overall Width

    2.812 inches nominal

  • Contact Adjustment Type

    external actuation point screw

  • Operating Temp Rating

    245.0 deg fahrenheit maximum

  • Mounting Facility Pattern

    isosceles triangle

  • Contact Load Current Rating

    4.8 amperes inductive load sixth voltage

  • Contact Voltage Rating In Volts

    550.0 ac at sea level fourth voltage

  • Overall Height

    5.312 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Contact Voltage Rating In Volts

    440.0 ac at sea level third voltage

  • Shortest Horizontal Distance Between Mounting Centers

    0.656 inches nominal

  • Longest Horizontal Distance Between Mounting Centers

    2.406 inches nominal

  • Bulb Length

    6.000 inches nominal

  • Contact Voltage Rating In Volts

    550.0 dc at sea level eighth voltage

  • Frequency In Hertz

    60.0 second voltage

  • Contact Load Current Rating

    3.2 amperes inductive load fourth voltage

  • Terminal Type

    screw

  • Style Designator

    rectangular

  • Contact Voltage Rating In Volts

    440.0 dc at sea level seventh voltage

  • Media For Which Designed

    gas or liquid

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Frequency In Hertz

    60.0 third voltage

  • Contact Load Current Rating

    9.6 amperes inductive load fifth voltage

  • Frequency In Hertz

    60.0 first voltage

  • Hazardous Locations/Environmental Protection

    dustproof and watertight

  • Contact Load Current Rating

    2.5 amperes inductive load seventh voltage

  • Contact Voltage Rating In Volts

    230.0 dc at sea level sixth voltage

  • Contact Load Current Rating

    2.0 amperes inductive load eighth voltage

  • Features Provided

    electrical access port

  • Body Height

    2.750 inches nominal

  • Longest Vertical Distance Between Mounting Centers

    3.281 inches nominal

  • Contact Load Current Rating

    8.0 amperes inductive load second voltage

  • Frequency In Hertz

    60.0 fourth voltage

  • Overall Length

    5.188 inches nominal

  • Capillary Tube Length

    120.0 inches nominal

  • Contact Load Current Rating

    16.0 amperes inductive load first voltage

  • Contact Action Stimulus

    increase

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...