ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4
-
Thread Quantity Per Inch
24
-
Nominal Thread Size
0.190 inches
-
Winding Tap Location
neutral tap
-
Winding Operating Voltage
2.80 ac volts nominal
-
Body Width
3.660 inches maximum
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.120 inches nominal
-
Body Length
5.340 inches maximum
-
Input-Output Phase Relationship
three phase to single phase
-
Thread Direction
right-hand
-
Thread Class
2a
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal
-
Frequency Rating
400.0 hertz minimum and 440.0 hertz maximum
-
Winding Shielding Method
internal shield grounded to core
-
Body Height
3.100 inches maximum
-
Inclosure Type
hermetically sealed
-
Mounting Method
threaded stud
-
Winding Function And Quantity
1 primary and 2 secondary
-
Winding Operating Current
10.0 amperes dc maximum
-
Winding Operating Current
19.5 amperes dc maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
18.90 ac volts nominal
-
Thread Series Designator
unc
-
Terminal Type And Quantity
9 solder stud