6990-32891
Circuit Breakers
CIRCUIT BREAKER
6990-32891
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Body Width
1.875 inches nominal
-
Nominal Thread Size
0.190 inches
-
Reset Method
manual
-
Thread Series Designator
unf
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Actuator Position Designation
at pole one
-
~1
data on certain environmental and performanc
-
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
-
Center To Center Distance Between Terminals Parallel To Length
1.063 inches nominal
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
End Item Identification
forrestal class cv; landing craft air cushion (lcac); shipboard material handling equipment (mhe)
-
Test Data Document
81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Manual Actuator Type And Quantity
1 push button
-
Mounting Facility Type And Quantity
2 threaded hole
-
Mounting Surface To Terminal End Distance
1.625 inches maximum
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Overall Length
3.227 inches nominal
-
Inclosure Protection Type For Which Designed
vibration resistant and salt spray proof and shock resistant and fungus resistant
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Specification/Standard Data
81349--13516/4 government specification
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud