SM3-5-115VAC60CPS58

Circuit Breakers

CIRCUIT BREAKER

SM3-5-115VAC60CPS58

5925-00-702-1924

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.375 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Nominal Thread Size

    0.375 inches

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • ~1

    single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Thread Series Designator

    unef

  • Frequency In Hertz

    60.0 single location

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Body Width

    0.625 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 maximum at 200 pct single location and 0.100 minimum at 200 pct single location and 0.020 minimum at 300 pct single location and 0.010 minimum at 400 pct single location and 0.130 maximum at 300 pct single location and 0.050 maximum at 400 pct

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...