AM17-7-5-208-56-400

Circuit Breakers

CIRCUIT BREAKER

AM17-7-5-208-56-400

5925-00-720-9790

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    4a single pole type

  • Case Material

    plastic

  • Iii Fragility Factor

    moderately rugged

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.280 minimum at 200 pct and

  • Thread Series Designator

    unc

  • Body Length

    2.500 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Pole Quantity

    1

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Frequency In Hertz

    400.0 single location

  • Terminal Type And Quantity

    2 screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...