Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Transformer Winding Connection Type
wye-wye
-
Body Length
6.800 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal single mounting facility single center group
-
Body Width
3.750 inches maximum
-
Nominal Thread Size
0.164 inches single group
-
Maximum Operating Temp
230.0 deg celsius
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Input-Output Phase Relationship
three phase to three phase single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.250 inches nominal single mounting facility single center group
-
Body Height
4.935 inches maximum
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Thread Series Designator
unc single group
-
Winding Operating Current
120.0 milliamperes dc nominal single component single secondary
-
Winding Operating Voltage
4.796 ac kilovolts nominal single component single secondary
-
Thread Direction (Non-Core)
err-070
-
Terminal Type And Quantity
8 tab, solder lug
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary