50-142-3MG3TDC12

Circuit Breakers

CIRCUIT BREAKER

50-142-3MG3TDC12

5925-00-724-7017

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

  • Unpackaged Unit Weight

    9.750 ounces

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Inclosure Protection Type For Which Designed

    moisture proof and shock resistant and explosion proof and fungus proof and vibration resistant

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    3.329 inches nominal

  • Case Material

    plastic

  • Body Width

    0.980 inches minimum and 1.090 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...