3MC8-3RC50

Circuit Breakers

CIRCUIT BREAKER

3MC8-3RC50

5925-00-726-0100

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Width

    0.665 inches nominal

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Inclosure Protection Type For Which Designed

    sand resistant and shock resistant and vibration resistant and fungus resistant and moisture resistant and corrosion resistant and dusttight

  • Trip Release Characteristic

    instantaneous single location

  • Body Style

    single pole type

  • Body Length

    1.781 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Bushing Length

    0.290 inches nominal

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 28.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 32.0 dc single location

  • Unpackaged Unit Weight

    2.000 ounces

  • Center To Center Distance Between Terminals Parallel To Length

    1.500 inches nominal

  • Mounting Surface To Terminal End Distance

    1.669 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac single location and 50.0 milliamperes dc single location

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...