AP12-51C

Circuit Breakers

CIRCUIT BREAKER

AP12-51C

5925-00-727-3832

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    1.875 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc first location

  • Thread Series Designator

    unef

  • Bushing Length

    0.375 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Terminal Type And Quantity

    4 wire hook

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...