SM33-1DC2AND17-10018
Circuit Breakers
CIRCUIT BREAKER
SM33-1DC2AND17-10018
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.375 inches maximum
-
Body Length
1.562 inches maximum
-
Body Width
1.281 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
thd bushing
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Trip Release Method
magnetic
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 125 pct and 7.000 maximum at 125 pct and 0.050 minimum at 200 pct and 0.950 maximum at 200 pct and 0.240 nominal at 400 pct
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Ultimate Trip Time Per Pole In Seconds
1.250 nominal
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Test Data Document
18876-1104658 drawing
-
Terminal Type And Quantity
4 wire hook