375D413G14

Circuit Breakers

CIRCUIT BREAKER

375D413G14

5925-00-727-7551

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Body Width

    4.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.187 inches nominal

  • Pole Quantity

    3

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    75.0 amperes ac and 75.0 amperes dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    300.000 minimum at 200 pct and 900.000 maximum at 200 pct all locations

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Length

    6.500 inches nominal

  • Body Height

    3.875 inches nominal

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.312 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac and 250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac and 10000.0 dc all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +900.0/+1050.0 ac and +900.0/+1050.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 quick disconnect, female

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...