Technical Characteristics

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Body Width

    1.281 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    unef

  • Switch Current Rating And Type In Amps

    0.5 dc

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum all locations and 7.000 maximum all locations

  • Switch Location And Position Designation

    internal at each pole

  • Body Length

    1.562 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    0.865 inches minimum and 0.885 inches maximum

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Terminal Type And Quantity

    4 wire hook

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Switch Terminal Type

    wire hook

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes dc all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Pole Quantity

    2

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...