GC20C5R00

Circuit Breakers

CIRCUIT BREAKER

GC20C5R00

5925-00-731-7477

5925 - Circuit Breakers

Northrop Grumman Systems Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Precious Material And Location

    terminal surfaces silver

  • Terminal Type And Quantity

    2 tab w/screw

  • Bushing Length

    0.250 inches maximum

  • Body Width

    0.750 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Reset Actuator Voltage Rating And Type In Volts

    120.0 ac and 30.0 dc

  • Fragility Factor

    moderately rugged

  • Reset Method

    electric

  • Actuator Function

    trip w/separate reset

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Body Length

    1.137 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    0.650 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...