1580-003-5

Circuit Breakers

CIRCUIT BREAKER

1580-003-5

5925-00-732-1929

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.690 inches minimum and 0.710 inches maximum

  • Mounting Surface To Terminal End Distance

    1.843 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Precious Material And Location

    contact surfaces silver

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 ac single location and 6000.0 dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Body Length

    1.127 inches minimum and 1.147 inches maximum

  • Trip Release Method

    thermal-magnetic single location

  • Nominal Thread Size

    0.138 inches

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.800 minimum at 200 pct single location and 3.600 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.240 inches minimum and 0.260 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    91.0 grams

  • Case Material

    plastic

  • Body Width

    0.750 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.