80132
Coils and Transformers
TRANSFORMER,POWER
80132
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
-
Body Length
6.000 inches maximum
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Frequency Rating
60.0 hertz nominal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
4.875 inches nominal single mounting facility single center group
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary and 7.00 ac volts nominal single component 2nd secondary
-
Inclosure Type
hermetically sealed
-
Winding Operating Current
2.5 amperes ac maximum single component 3rd secondary
-
Terminal Type And Quantity
9 standoff, solder lug
-
Winding Operating Current
24.0 amperes ac maximum single component 2nd secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Mounting Facility Quantity
4 single group
-
Body Height
6.125 inches maximum
-
Winding Operating Current
17.0 amperes ac maximum single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
5.250 inches nominal single mounting facility single center group
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Maximum Operating Temp
75.0 deg celsius
-
Winding Operating Voltage
7.30 ac volts nominal single component 3rd secondary
-
Body Width
5.625 inches maximum
-
Mounting Hole Diameter
0.281 inches nominal single group
-
Winding Tap Location (Non-Core)
err-070