Technical Characteristics

  • Overall Width

    8.250 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 32.000 maximum at 200 pct all locations

  • Overall Height

    5.420 inches nominal

  • Case Material

    plastic

  • Unpackaged Unit Weight

    58.000 pounds

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +3000.0/+6000.0 ac all locations

  • Body Style

    rectangular dimensional envelope

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Overall Length

    24.523 inches nominal

  • Features Provided

    adjustable trip release and current limiter

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    600.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100000.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Inclosure Protection Type For Which Designed

    general purpose

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...