9176315-1

Circuit Breakers

CIRCUIT BREAKER

9176315-1

5925-00-735-5434

5925 - Circuit Breakers

U S Army Aviation And Missile

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    1.030 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Length

    3.060 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.030 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Width

    3.062 inches nominal

  • Ultimate Trip Time Per Pole In Seconds

    50.000 nominal all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Surface To Terminal End Distance

    3.530 inches nominal

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Length

    3.719 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...