43962-1
Coils and Transformers
TRANSFORMER,POWER
43962-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
16 wire lead
-
Winding Operating Voltage
305.00 ac volts nominal and 333.00 ac volts nominal
-
Winding Operating Current
56.0 milliamperes ac maximum
-
Winding Operating Current
2.0 milliamperes ac maximum
-
Winding Operating Voltage
84.00 ac volts nominal
-
Winding Operating Voltage
640.00 ac volts nominal and 695.00 ac volts nominal
-
Winding Operating Voltage
335.00 ac volts nominal and 357.00 ac volts nominal
-
Winding Operating Voltage
18.00 ac volts nominal and 90.00 ac volts nominal and 103.00 ac volts nominal
-
Winding Operating Current
410.0 milliamperes ac maximum
-
Winding Operating Current
203.0 milliamperes ac maximum
-
Winding Tap Location
tap w/o center tap
-
Winding Function And Quantity
1 primary and 4 secondary
-
Inclosure Type
open
-
Body Width
2.187 inches nominal
-
Winding Shielding Method
internal shield grounded to inclosure
-
Input-Output Phase Relationship
single phase to single phase
-
Mounting Slot Width
0.187 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.187 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.750 inches nominal
-
Reliability Indicator
not established
-
Winding Tap Location
multiple taps w/center tap
-
Mounting Method
flange and slot
-
Mounting Facility Quantity
4
-
Body Height
3.500 inches nominal
-
Body Length
3.812 inches nominal
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum