MS25337-35

Circuit Breakers

CIRCUIT BREAKER

MS25337-35

5925-00-752-6433

5925 - Circuit Breakers

Military Standards

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Specification/Standard Data

    96906-ms25337 government standard

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Trip Release Method

    thermal single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 3000.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    2.189 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Case Material

    metal

  • Pole Quantity

    1

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...