3XAM1516MG3-5AMP416VAC400C2

Circuit Breakers

CIRCUIT BREAKER

3XAM1516MG3-5AMP416VAC400C2

5925-00-755-2461

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.156 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    3.310 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.062 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Width

    3.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.062 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    3.062 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    14.000 minimum at 150 pct all locations and 2.000 minimum at 300 pct all locations and 20.000 maximum at 200 pct all locations and 50.000 maximum at 150 pct all locations and 6.000 minimum at 200 pct all locations and 6.500 maximum at 300 pct all

  • ~1

    locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Length

    3.790 inches maximum

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1300.0 ac single location

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...