53-119MG3-3-416VAC2-400HZ

Circuit Breakers

CIRCUIT BREAKER

53-119MG3-3-416VAC2-400HZ

5925-00-755-5078

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.021 inches minimum and 1.041 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Precious Material And Location

    terminal surfaces silver

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.021 inches minimum and 1.041 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1300.0 ac all locations

  • Manual Actuator Type And Quantity

    6 toggle

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Width

    3.042 inches minimum and 3.062 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    1.850 pounds

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...