9063046-10
Circuit Breakers
CIRCUIT BREAKER
9063046-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1300.0 ac all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Boss Height
0.146 inches minimum and 0.166 inches maximum
-
Precious Material And Location
terminal surfaces silver
-
Frequency In Hertz
400.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Operating Voltage Type And Rating Per Pole In Volts
416.0 ac all locations
-
Thread Series Designator
unc
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged
-
Terminal Type And Quantity
6 threaded stud
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
1.365 inches minimum and 1.385 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.365 inches minimum and 1.385 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Mounting Facility Type And Quantity
6 threaded hole
-
Mounting Surface To Terminal End Distance
3.177 inches minimum and 3.301 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Body Width
3.052 inches minimum and 3.072 inches maximum
-
Body Style
multipole-multiple actuator type
-
Unpackaged Unit Weight
1.000 pounds
-
Trip Release Method
magnetic-hydraulic all locations
-
Thread Quantity Per Inch
32
-
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct all locations and 10.000 minimum at 200 pct all locations
-
Body Length
3.708 inches minimum and 3.728 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Precious Material
silver
-
Center To Center Distance Between Terminals Parallel To Length
3.052 inches minimum and 3.072 inches maximum