6760-1-35

Circuit Breakers

CIRCUIT BREAKER

6760-1-35

5925-00-755-5798

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.712 inches minimum and 0.774 inches maximum

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    1.156 inches minimum and 1.218 inches maximum

  • Fragility Factor

    moderately rugged

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.796 inches minimum and 1.828 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Height

    2.125 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    8.000 ounces

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Length

    2.203 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.470 inches minimum and 1.502 inches maximum

  • Trip Release Method

    thermal all locations

  • Body Width

    2.250 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...