Q531487048

Circuit Breakers

CIRCUIT BREAKER

Q531487048

5925-00-758-1839

5925 - Circuit Breakers

Rheinmetall Air Defence Ag

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant and fungus resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Specification/Standard Data

    96906-ms26574 government standard

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.780 inches maximum

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 30.0 dc

  • Terminal Type And Quantity

    2 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location and 800.0 dc single location

  • Body Width

    0.593 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.562 inches minimum and 0.624 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    0.066 pounds

  • Switch Terminal Type

    tab, solder lug

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.525 inches maximum

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Bushing Length

    0.217 inches minimum and 0.282 inches maximum

  • Switch Current Rating And Type In Amps

    2.0 ac and 3.0 dc

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...