7276-101-1
Circuit Breakers
CIRCUIT BREAKER
7276-101-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 9.000 maximum at 300 pct all locations
-
Thread Series Designator
uns
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Bushing Length
0.280 inches nominal
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.850 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Body Height
2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole two
-
Nominal Thread Size
0.468 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Body Style
multipole-single actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Width
1.341 inches nominal
-
Terminal Type And Quantity
6 screw
-
Body Length
2.000 inches maximum
-
Body Width
0.850 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations