72-281-3

Circuit Breakers

CIRCUIT BREAKER

72-281-3

5925-00-760-0475

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    moisture resistant and shock resistant and vibration resistant

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.924 inches minimum and 1.952 inches maximum

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.280 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Body Length

    2.530 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Boss Height

    0.155 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Unpackaged Unit Weight

    0.875 pounds

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations

  • Nominal Thread Size

    0.138 inches

  • Maximum Continuous Load Current Rating Per Pole

    12.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Test Data Document

    24930-g330024 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    2.570 inches minimum and 2.690 inches maximum

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...