Technical Characteristics

  • Body Length

    1.562 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Switch Location And Position Designation

    internal at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Thread Series Designator

    unef

  • Bushing Length

    0.330 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Body Width

    1.281 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Switch Terminal Type

    wire hook

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Terminal Type And Quantity

    4 wire hook

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum all locations and 7.000 maximum all locations

  • Frequency In Hertz

    400.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...