PDM6
Circuit Breakers
CIRCUIT BREAKER
PDM6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
1.250 inches nominal
-
Manual Actuator Type And Quantity
1 push button
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 ac single location and 575.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Surface To Terminal End Distance
1.266 inches nominal
-
Inclosure Protection Type For Which Designed
explosion resistant and vibration resistant
-
Pole Quantity
1
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches nominal
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac single location and 6.0 amperes dc single location
-
Unpackaged Unit Weight
1.750 ounces
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
-
Unthreaded Mounting Hole Diameter
0.190 inches nominal
-
Overall Length
2.000 inches nominal
-
Case Material
plastic
-
Terminal Type And Quantity
2 tab w/screw