MIS17330-1-5
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
MIS17330-1-5
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Travel Control Feature
stops
-
Tap Location From Ccw Terminal Per Section In Ohms
15000.0 6th section
-
Electrical Resistance Per Section
225.000 percent, rated amperes c and better industrial clears
-
Power Dissipation Rating Per Section In Watts
2.0 free air all sections
-
Tap Location From Ccw Terminal Per Section In Ohms
150000.0 1st section
-
Effective Electrical Rotation In Deg Angular Rotation
275.0 nominal
-
Body Length
3.934 inches nominal
-
Nonturn Device Radius
0.531 inches nominal
-
Body Style
cylindrical bushing mounted
-
Shaft Style
round, slotted
-
Function Characteristic Per Section
all sections linear
-
Electrical Resistance Per Section
300.000 percent, rated amperes c and better finish
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-20.0/+20.0 all sections
-
Terminal Type And Quantity
28 tab, solder lug
-
Electrical Resistance Per Section
100.000 percent, rated amperes c and better select
-
Tap Location Tolerance Per Section
-2.0/+2.0 ohms all sections
-
Section Quantity
7
-
Body Diameter
1.625 inches nominal
-
Tap Location From Ccw Terminal Per Section In Ohms
37500.0 4th section
-
Screw Thread Diameter
0.375 inches nominal
-
Tap Location From Ccw Terminal Per Section In Ohms
25000.0 5th section
-
Tap Location From Ccw Terminal Per Section In Ohms
112500.0 2nd section
-
Rotary Actuator Travel In Angular Deg
300.0 nominal
-
Resistance Tolerance Per Section In Percent
-1.0/+1.0 all sections
-
Mounting Bushing Length
0.375 inches nominal
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Shaft Diameter
0.250 inches nominal
-
Fixed Tap Quantity Per Section
1 all sections
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
40.0 all sections
-
Maximum Starting Torque
6.00 inch-ounces
-
Function Conformity Per Section
all sections independent linearity
-
Electrical Resistance Per Section
30.000 percent, rated amperes c finish
-
Actuator Type
single shaft
-
Function Conformity Tolerance Per Section
-0.50/+0.50 all sections
-
Reliability Indicator
not established
-
Screw Thread Series Designator
unef
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
105.0 all sections
-
Electrical Resistance Per Section
50.000 percent, rated amperes c drop siding
-
Mounting Method
standard bushing
-
Electrical Resistance Per Section
5.000 percent, rated amperes c flooring
-
Maximum Running Torque
1.25 inch-ounces
-
Terminal Location
radially positioned over less than half the circumference
-
Features Provided
grounded contact arm
-
Shaft Length
0.875 inches nominal
-
Electrical Resistance Per Section
75.000 percent, rated amperes c and better v.g. stepping
-
Tap Location From Ccw Terminal Per Section In Ohms
2500.0 7th section
-
Tap Location From Ccw Terminal Per Section In Ohms
50000.0 3rd section
-
Screw Thread Quantity Per Inch
32.0