Technical Characteristics
-
Body Style
7a single pole type
-
Bushing Length
0.469 inches minimum and 0.499 inches maximum
-
Body Width
0.750 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Mounting Surface To Terminal End Distance
2.340 inches minimum and 2.400 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 threaded hole
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
205.0 ac single location and 30.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4200.0 ac single location and 6000.0 dc
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal-magnetic single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 minimum at 200 pct single location and 50.000 maximum at 200 pct
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
7.0 dc
-
Switch Voltage Rating And Type In Volts
28.0 dc
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 tab w/screw
-
Body Length
2.189 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.160 inches minimum and 1.220 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location and 35.0 amperes dc
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
explosion proof and humidity proof and corrosion resistant and dustproof and sand resistant and fungus resistant
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Frequency In Hertz
400.0 single location
-
Unpackaged Unit Weight
0.700 pounds