6752-14-35

Circuit Breakers

CIRCUIT BREAKER

6752-14-35

5925-00-764-2908

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    7a single pole type

  • Bushing Length

    0.469 inches minimum and 0.499 inches maximum

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Mounting Surface To Terminal End Distance

    2.340 inches minimum and 2.400 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac single location and 30.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac single location and 6000.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal-magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct single location and 50.000 maximum at 200 pct

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    2.189 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location and 35.0 amperes dc

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    explosion proof and humidity proof and corrosion resistant and dustproof and sand resistant and fungus resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    400.0 single location

  • Unpackaged Unit Weight

    0.700 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...