6752-302-10

Circuit Breakers

CIRCUIT BREAKER

6752-302-10

5925-00-764-2911

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    2.250 inches maximum

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.782 inches minimum and 1.842 inches maximum

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Switch Terminal Type

    turret

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Unpackaged Unit Weight

    2.100 pounds

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    1.158 inches minimum and 1.218 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 75.000 maximum at 200 pct all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    2.440 inches minimum and 2.500 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Body Length

    2.189 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac all locations and 6000.0 dc all locations

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac all locations and 28.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.490 inches minimum and 1.510 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    6 tab w/screw

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.