6752-302-50

Circuit Breakers

CIRCUIT BREAKER

6752-302-50

5925-00-764-2913

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole three

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    2.100 pounds

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Length

    2.189 inches maximum

  • Body Height

    2.440 inches minimum and 2.500 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.158 inches minimum and 1.218 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.720 inches minimum and 0.780 inches maximum

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac and 28.0 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 75.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and sandtight

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum

  • Switch Terminal Type

    turret

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.782 inches minimum and 1.842 inches maximum

  • Actuator Position Designation

    at pole two

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Body Width

    2.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.720 inches minimum and 0.780 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac and 50.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac and 6000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    thermal-magnetic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Reset Method

    manual

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.