GA51682
Coils and Transformers
TRANSFORMER,POWER
GA51682
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.594 inches minimum and 2.719 inches maximum
-
Winding Operating Voltage
17.00 ac volts nominal single component single secondary and 21.00 ac volts nominal single component single secondary and 19.00 ac volts nominal single component single secondary and 28.00 ac volts nominal single component single secondary
-
Nominal Thread Size
0.190 inches single group
-
Thread Series Designator
unc single group
-
Inclosure Type
hermetically sealed
-
Body Height
2.343 inches minimum and 2.531 inches maximum
-
Thread Quantity Per Inch
24 single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Class (Non-Core)
err-070
-
Reliability Indicator
not established
-
Frequency Rating
380.0 hertz minimum single component and 426.0 hertz minimum single component
-
Distance Between Mounting Facility Centers
1.782 inches nominal single mounting facility single center group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary
-
Overall Height
3.250 inches maximum
-
Mounting Method
threaded stud single group
-
Winding Tap Location (Non-Core)
err-070
-
Terminal Type And Quantity
9 wire hook
-
Mounting Facility Quantity
2 single group
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Body Width
2.406 inches minimum and 2.531 inches maximum
-
Maximum Operating Temp
95.0 deg celsius
-
Winding Operating Current
2.0 amperes ac maximum single component single secondary