6752-12-2

Circuit Breakers

CIRCUIT BREAKER

6752-12-2

5925-00-766-8538

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-27715 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct single location and 32.000 maximum at 200 pct single location

  • Actuator Function

    trip-reset

  • Body Width

    0.760 inches maximum

  • Mounting Surface To Terminal End Distance

    2.370 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Specification/Standard Data

    96906-ms24571 government standard

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location and 2.5 amperes dc single location

  • Unpackaged Unit Weight

    0.200 pounds

  • Manual Actuator Type And Quantity

    1 push-pull

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    shock resistant and vibrationproof and dustproof and corrosion resistant and hermetically sealed and explosion proof and humidity resistant and salt spray proof and sand resistant and fungus resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.187 inches minimum and 0.249 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    2.189 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...