711525-24

Circuit Breakers

CIRCUIT BREAKER

711525-24

5925-00-768-3364

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 40.000 maximum at 200 pct single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    0.700 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    7a single pole type

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    2.340 inches minimum and 2.400 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac and 7.5 amperes dc single location

  • Trip Release Method

    thermal-magnetic single location

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole one

  • ~1

    d resistant and sand resistant

  • Inclosure Protection Type For Which Designed

    explosion proof and humidity proof and corrosion resistant and dustproof and san

  • Switch Terminal Type

    tab, solder lug

  • Bushing Length

    0.469 inches minimum and 0.499 inches maximum

  • Body Length

    2.189 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac and 30.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac and 6000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...