154650-003

Circuit Breakers

CIRCUIT BREAKER

154650-003

5925-00-774-2947

5925 - Circuit Breakers

Xerox Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Features Provided

    handle lock

  • Trip Release Characteristic

    time delay all locations

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.220 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Switch Location And Position Designation

    external at pole one

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct all locations and 60.000 maximum at 150 pct all locations and 2.200 minimum at 200 pct all locations and 6.000 minimum at 150 pct all locations and 0.300 minimum at 400 pct all locations and 2.300 maximum at 400 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Bushing Length

    0.130 inches nominal

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Ultimate Trip Time Per Pole In Seconds

    175.000 maximum all locations

  • Switch Terminal Type

    solder stud

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...