TM1/8 502K
Resistors
RESISTOR,THERMAL
TM1/8 502K
Texas Instruments Incorporated
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 10th resistance-temperature point
-
Zero Power Resistance At Specified Temp
7.1 kilohms 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.8/+12.8 4th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-16.1/+16.1 1st resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Zero Power Resistance At Specified Temp
6.0 kilohms 6th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-25.0 deg celsius 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
3.3 kilohms 4th resistance-temperature point
-
Maximum Operating Temp
150.0 deg celsius
-
Zero Power Resistance At Specified Temp
10.0 kilohms 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
125.0 deg celsius 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 6th resistance-temperature point
-
Zero Power Resistance
5.000 kilohms
-
Body Outside Diameter
0.125 inches minimum and 0.155 inches maximum
-
Ambient Temp At Full Rated Power
100.0 deg celsius
-
Resistance Tolerance At A Specified Temp In Percent
-16.2/+16.2 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-14.3/+14.3 7th resistance-temperature point
-
Zero Power Resistance At Specified Temp
11.2 kilohms 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
75.0 deg celsius 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-18.5/+18.5 9th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-50.0 deg celsius 3rd resistance-temperature point
-
Terminal Surface Treatment
tin
-
Zero Power Resistance At Specified Temp
8.4 kilohms 8th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-10.3/+10.3 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.1/+12.1 6th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-75.0 deg celsius 1st resistance-temperature point
-
Terminal Diameter
0.025 inches nominal
-
Zero Power Resistance At Specified Temp
2.4 kilohms 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 5th resistance-temperature point
-
Style Designator
rod
-
Terminal Type And Quantity
2 wire lead
-
Zero Power Resistance At Specified Temp
4.1 kilohms 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-14.6/+14.6 3rd resistance-temperature point
-
Reliability Indicator
not established
-
Maximum Power Dissipation Rating
125.00 milliwatts
-
Thermal Time Constant In Seconds
34.8
-
Resistance Tolerance At A Specified Temp In Percent
-15.0/+15.0 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-65.0 deg celsius 2nd resistance-temperature point
-
Inclosure Type
encapsulated
-
Zero Power Resistance At Specified Temp
2.7 kilohms 3rd resistance-temperature point
-
Zero Power Resistance At Specified Temp
2.2 kilohms 1st resistance-temperature point
-
Body Length
0.390 inches minimum and 0.420 inches maximum
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Zero Power Temp Coefficient Of Resistance In Percent Per Deg Celsius
0.70
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 8th resistance-temperature point
-
Terminal Length
1.375 inches minimum and 1.625 inches maximum