075934

Circuit Breakers

CIRCUIT BREAKER

075934

5925-00-776-2620

5925 - Circuit Breakers

New Holland Construction

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Body Length

    1.782 inches minimum and 1.844 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Body Width

    1.157 inches minimum and 1.219 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.064 inches minimum and 1.126 inches maximum

  • Trip Release Method

    thermal single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.543 inches minimum and 1.605 inches maximum

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 nominal at 200 pct single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Unpackaged Unit Weight

    2.250 ounces

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    600.0 dc single location

  • Reset Method

    automatic

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Case Material

    plastic

  • Body Height

    1.676 inches minimum and 1.738 inches maximum

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Unthreaded Mounting Hole Diameter

    0.174 inches nominal

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and waterproof and dustproof and fungus resistant

  • Terminal Type And Quantity

    2 pin

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...