Technical Characteristics

  • Body Style

    single pole type

  • Body Length

    2.188 inches maximum

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc

  • Trip Release Method

    thermal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Terminal Type And Quantity

    2 screw

  • Specification/Standard Data

    96906-ms27410 government standard

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 maximum

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 100.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Test Data Document

    81349-mil-c-7079 specification

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...