712A601

Circuit Breakers

CIRCUIT BREAKER

712A601

5925-00-781-2716

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.500 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Bushing Length

    0.380 inches maximum

  • Body Width

    1.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    600.0 milliamperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    shunt trip

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof and hermetically sealed

  • Terminal Type And Quantity

    6 wire hook

  • Thread Series Designator

    unef

  • Frequency In Hertz

    50.0 or b60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and 0.550 maximum at 200 pct

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Time Per Pole In Seconds

    1.000 minimum and 4.000 maximum

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...